Cellwrite Studio operating manual · CWS-OM-001, revision A
Safety
General
Cellwrite Studio reads, checks and changes robot programs. A changed program moves a robot differently. Read this chapter before you send a program to a robot.
Warning
Cellwrite Studio is not a safety function. Its collision checks, interference analysis, simulation and code checks help you find problems before a program runs. They do not replace the robot's safety controller (for example SafeMove), the cell's guarding or the site's procedures.
Before you load a changed program
- Check the program with Check program (F8) and correct what is marked as an error.
- Compare the changed program with the program that runs on the robot (Compare).
- Load the program with the robot in manual mode, at reduced speed.
- Run the changed part step by step from the FlexPendant, with the hold-to-run device, and watch the robot.
- Run it at full speed only when it has run correctly at reduced speed.
Simulation and 3D
The 3D views show the robots, tools and fixtures from the backups and the cell layout. The tool shapes are made from the tool data, the payload and the SafeMove shapes in the backup. They are close to the real tools, but they are not the real tools.
Caution
A move that is clear in Cellwrite Studio can still collide in the cell. Cables, dress packs, parts and anything not in the backup are not drawn.
Live connection
When Cellwrite Studio is connected to a robot it only reads, until you ask for write access and the operator grants it on the FlexPendant. While Cellwrite Studio holds write access, the FlexPendant cannot change the program.
Warning
Never apply a change to a robot that someone is working near or that is running in automatic mode, unless the site's procedure allows it.
- Release write access when you have finished: Release write access in the top bar, or Live > Access.
- Apply sends only the modules you changed. The robot's program is read again first, so a change made on the FlexPendant in the meantime is not overwritten without a warning.
- Undo last apply puts the modules back as they were before the last apply.
PLC
Cellwrite Studio never writes to a PLC. The PLC editor works on an L5X file. Load a changed program into the PLC with Studio 5000, following the site's procedure.
SafeMove
The SafeMove zones shown in the cell are read from the backup and checked by Cellwrite Studio, not by SafeMove. A safety configuration is changed and validated only with the tools ABB provides for it.